3M™ Full Face Mask Replacement Filters 6098
The 3M™ Gas and Vapour filter 6098, AXP3 can be used where protection against low boiling point (<650 C) organic compounds and particulates is required. It is designed to be used with 3M Full Face respirators only.
Priced on the day, in meticais
Description
The 3M™ Gas and Vapour Filter 6098 contains activated carbon and conforms to EN 14387. It is designed to be used with 3M Full Face respirators only. The filter can provide protection against low boiling point (<650 C) organic compounds and particulates.
Main Features
- Good balance of weight on face.
- Excellent field of vision as a result of unique trapezoidal shape.
- Bayonet fitting ensures precise & safer locking to 3M Full Face respirators.
Applications
3M™ Gas and Vapour Cartridge 6098 is a unique filter cartridge that is able to offer protection from low boiling point (<650 C) organic vapors as well as solid particulate contaminants such as dust, oil mist, and metal fumes. The high-efficiency P3 Particle Filter built into this product is designed for a maximum length of service and ease of maintenance. They can be installed easily, with one person, in less than five minutes!
Storage and Transportation.
Do not store outside the temperature range -10°C to +50°C or with humidity above 90%. When stored as stated, the expected shelf life of the product is 5 years from the date of manufacture. The end of shelf life (use-by) date is marked on the product and packaging. The original packaging is suitable for transporting the product. Better still, 3M assigns a unique part number on each unit, so when the gas- and vapor-tight package is penetrated, its contents are tracked back to an individual part number. That's only one more way 3M helps you get it right - from first use to the final disposal.
Warnings and Use limitations.
Limitations on the use of these filters may differ among countries. 3M recommends the following should be applied in the absence of specific recommendations in South Africa.
Low boiling point organic compounds against which the 3M™ Gas and Vapour filter 6098, AXP3 may be used are divided into groups:
| Group | Maximum Concentration (ppm) | Maximum Usage Time (minutes) |
|---|---|---|
| Group1 | 100 ppm | 40 mins |
| Group 1 | 500 ppm | 20 mins |
| Group 2 | 1000 ppm | 60 mins |
| Group 2 | 5000 ppm | 20 mins |
Proper selection, training, use, and appropriate maintenance are essential in order for the product to help protect the wearer from certain airborne contaminants.
Failure to follow all instructions on the use of these respiratory protection products and/or failure to properly wear the complete product during all periods of exposure may adversely affect the wearer’s health, lead to severe or life-threatening illness or permanent disability.
Always be sure that the complete product is:
- Suitable for the application;
- Fitted correctly;
- Worn during all periods of exposure;
- Replaced when necessary.
For suitability and proper use follow local regulations, refer to all information supplied or contact an occupational hygienist, safety professional, or 3M representative on the Tech Assist Helpline.
- Do not submerge the filters in liquid.
- Do not use these products inflammable or explosive atmospheres.
- Do not use in atmospheres containing less than 19.5% oxygen. (3M definition. Individual countries may apply their own limits on oxygen deficiency. Seek advice if in doubt).
- Do not use for respiratory protection against atmospheric contaminants/concentrations which have poor warning properties or are unknown or immediately dangerous to life and health (IDLH) or against contaminants/concentrations which generate high heats of reaction with chemical filters.
- Do not use these products when working with open flames or liquid metal droplets.
- Do not use these products in pure oxygen or oxygen-enriched atmospheres.
- Do not use in concentrations above those specified in Warning and Use Limitations.
- In case of intended use in explosive atmospheres, contact 3M Technical Service.
- Leave the contaminated area immediately if:
a) Any part of the system becomes damaged.
b) Airflow to the facepiece decreases or stops.
c) Breathing becomes difficult or increased breathing resistance occurs.
d) Dizziness or other distress occurs.
e) You smell or taste contaminants or irritation occurs. - Never alter, modify or repair this device.
- These products do not contain components made from natural rubber latex.
Also in this range

3M™ - Reusable Full Face Mask
Add to quote →
3M™ Half and Full Face Mask Replacement Filters 6057
Add to quote →
3M™ - Reusable Half Face Mask - 6000 Series
Add to quote →
3M Safety Goggles GoggleGear 2890 Series
Add to quote →
3M Safety Goggles GoggleGear 500 Series
Add to quote →
3M Safety Goggles 4800 Series
Add to quote →
3M Safety Goggles 4700 Series
Add to quote →
3M Safety Glasses SecureFit 500 Series
Add to quote →How quoting works
Send your list or RFQ
Add products to your quote, or attach the spreadsheet, PDF or photo you already have. WhatsApp and email work too.
Priced on the day, in meticais
At today's exchange rate, by size and quantity, with the validity period stated on the quote.
Supplied to your site
From Chingodzi, Tete, with personal follow-through on the ground. Send your purchase order with the quote reference.
Common questions
How often should respirator filters be changed?
It depends on the dust or gas concentration and hours of use; follow the manufacturer's guidance and your SHE officer. We can quote filters in bulk for regular replacement.
Why are there no prices?
Our stock is imported and the rand–metical exchange rate moves daily. We price on the day, in meticais, so you never pay for yesterday's exchange rate.
Send your list. We quote today.
Boots, workwear and protection for your crew, priced in meticais on the day.